Current probe capturing the inrush current peak of a power supply on an oscilloscope
Inrush peak captured single-shot at the mains voltage peak.
Posted in

How to Measure Inrush Current and Check Datasheet Limits

Inrush current is the surge a product draws in the first milliseconds after power-on. It blows fuses, trips breakers, welds relay contacts and stresses bridge rectifiers, yet it is often measured wrongly: with the bandwidth limit on, in Auto trigger mode, at a random switch-on angle, or with no clear idea of which part of the waveform the datasheet limit refers to. This guide shows engineers and technicians how to measure inrush current correctly, how to read the inrush specifications in datasheets, and how to use your measurement to decide pass or fail.

The illustrations in this guide are live: click the buttons under each one to change the setup and watch the result change.

1. What Is Inrush Current?

When an AC-DC power supply is switched on, its bulk capacitor is empty. For a moment, the only things limiting the current are the line impedance, the bridge rectifier, the capacitor ESR and any inrush limiter such as an NTC thermistor:

Ipk ≈ Vpk / (RNTC + Rline + Rbridge + ESR)

A typical inrush event has up to three parts:

  • EMI filter spike: the X-capacitors charge in a few microseconds. Very high peak, almost no energy.
  • Bulk capacitor charging pulse: the main inrush, lasting from a fraction of a millisecond to a few milliseconds, followed by smaller pulses on the next half-cycles.
  • Second events: an NTC bypass relay closing, a PFC stage starting, or a DC-DC converter charging its output capacitors, often tens to hundreds of milliseconds later.

Transformers (magnetizing inrush), motors, lamps and hot-plugged DC boards have their own inrush, but the measurement method is the same.

Switch-on: NTC: Mode:
Simulated 230 V, 50 Hz capacitor-input supply: 470 µF bulk, NTC 10 Ω cold / 1.5 Ω hot, 1 Ω line and bridge. Yellow is current, blue is line voltage.

2. How to Read Inrush Specifications in Datasheets

An inrush number is meaningless without its conditions. Read the whole line, the footnotes and the test-condition section.

Power supply or module datasheet

What the datasheet saysWhat to check
“Inrush current: 40 A max”Is it max or typical? A typical value is not a limit.
“at 230 V AC” / “at 115 V AC”Inrush scales with the input peak voltage. 264 V AC gives about 15 % more than 230 V AC.
“cold start, 25 °C”A hot restart gives a higher peak with an NTC limiter. Ask the maker if hot restart is not specified.
“first half-cycle” / “excluding EMI filter charging current (under 0.2 ms)”Tells you which part of the waveform the limit applies to and which spikes are excluded.
Measurement source impedanceSome specs assume a defined line impedance. A stiff lab source gives higher inrush than a weak one.
Duration or I²tSome datasheets also give a duration (for example “under 10 ms”) or I²t. Use them for fuse and breaker selection.

Fuse datasheet

  • Melting I²t (A²s): the energy that opens the fuse. Compare it with your measured I²t, not the peak current.
  • Pulse derating: repeated inrush pulses age the element. A widely used fuse-maker guideline allows about 38 % of melting I²t for 1,000 pulses, 29 % for 10,000 and 22 % for 100,000. Use your fuse maker’s own figures where available.
  • Time-current curve: fast-acting (F) fuses tolerate much less inrush than time-lag (T) fuses.

Bridge rectifier datasheet

  • IFSM (peak forward surge current) is specified for a single 8.3 ms (60 Hz) or 10 ms (50 Hz) half-sine pulse. Your inrush pulse is usually much shorter, so comparing your peak with IFSM is conservative.
  • I²t rating (for t under 8.3 ms) is the better comparison for short pulses.
  • Check whether the rating is at TJ = 25 °C or at operating temperature; a hot restart happens with a warm bridge.

NTC thermistor datasheet

  • R25 sets the cold inrush. Resistance at operating current (often well under 1 Ω) sets the hot-restart inrush.
  • Maximum capacitance at a given voltage (or maximum energy ½CV²): your bulk capacitor must be within it.
  • Cool-down time: an NTC can take a minute or more to recover. Repeated on/off cycles give high inrush.

Relays, switches and breakers

  • Relay and switch datasheets give an inrush or make current rating (for example UL “TV” ratings for lamp loads). Compare with your measured peak.
  • Miniature circuit breakers trip instantaneously at 3 to 5 × In (type B), 5 to 10 × In (type C) or 10 to 20 × In (type D). Several units switched on together add their inrush.
  • Some standards and customers define an inrush time-current mask (for example telecom -48 V DC equipment). The measured current must stay under the mask at every point in time.

3. Equipment and Safety

ItemNotes
AC/DC current probe (Hall-effect clamp)Peak current rating above your worst case (including hot restart), bandwidth of a few MHz or more. Degauss and zero before every capture.
Current shunt + differential probeAlternative to a clamp. Low-inductance shunt rated for the pulse energy. Never use a grounded passive probe on mains.
High-voltage differential probeLine voltage on a second channel, to confirm the switch-on angle.
AC source with phase-angle controlSwitches on at exactly 90° (line peak). Otherwise use a zero-cross/peak-switching relay, or repeat many random switch-ons.
Oscilloscope with deep memoryLong single-shot captures (up to 1 s) at a high sample rate.
Safety: never float the oscilloscope by removing its protective earth. Use differential or isolated probes and CAT-rated equipment.

4. Scope and Probe Settings

SettingUseWhy
Bandwidth limitOFFNarrow pulses and the EMI-filter spike lose amplitude with a filter.
CouplingDCAC coupling distorts a single pulse.
Probe ratio and unitsAmps, ratio matching the probe rangeFor example 100 mV/A on the 30 A range.
Vertical scaleExpected peak in about 5 divClipping hides the true peak. Estimate it first with the calculator.
Sample rate≥ 1 MS/s for the main pulse; ≥ 50 MS/s to see the X-cap spikeCheck the rate the scope actually uses at your timebase and record length.
AcquisitionSample or peak detectNever average a single event.

5. Capturing the Inrush Event

  • Single-shot mode. Inrush happens once; Auto mode re-arms and loses it.
  • Trigger: edge on the current channel, either slope (the first pulse can be negative), at about 10 % of the expected peak, above the noise.
  • Pre-trigger 10 to 20 %, so the moment of switch-on is visible.
  • Switch on at the line peak (90°). At 0° the capacitor charges gently and the inrush is much lower.
  • Capture several windows (or one long, deep-memory capture and zoom): see the next section.

6. What to Measure: Level and Time Frame

“The inrush” is not one number. Measure and report each of these, and state which one the datasheet limit refers to:

QuantityDefinitionTimebase
X-cap spike peakHighest current in the first microseconds (EMI filter charging). Report separately; many specs exclude it.10 to 50 µs/div
Inrush peak IpkHighest instantaneous |i| of the bulk-capacitor charging pulse. This is the value most specs mean.0.5 to 2 ms/div
Time to peak, pulse widthFrom switch-on to peak; width at 50 % of the peak.0.5 to 2 ms/div
Event durationFrom switch-on until the line-current peaks settle within about 110 % of their steady-state value (or the % your spec defines).10 to 20 ms/div
I²t∫ i² dt over the event (scope math: square, then integrate). Use the first half-cycle for bridge I²t, the whole event for fuses.10 to 20 ms/div
Second eventsRelay bypass, PFC start, DC-DC start-up, downstream loads.50 to 100 ms/div
Zoom:
One cold start at 230 V AC, switched on at 90°, viewed at four timebases. The NTC bypass relay closes and the converter starts at 250 ms.
Key point: always report the peak together with its time frame, for example “52 A peak, 0.9 ms wide at 50 %, event duration 60 ms, I²t 2.1 A²s, excluding a 10 µs X-cap spike of 58 A”.

7. Worst-Case Conditions

  • Maximum input voltage (for example 264 V AC): peak current scales with Vpk.
  • Switch-on at 90° every time, or at least 20 to 30 random switch-ons and take the maximum.
  • Hot restart: run at full load until warm, switch off for 1 to 2 s (bulk cap discharged by the load, NTC still hot), switch on.
  • Cold start at minimum ambient if the bridge or capacitors change much with temperature.
  • Bulk capacitor fully discharged before each cold test.
  • Output load as in the application; some converters start into their full load.

8. Pass or Fail: Checking Against the Limits

Use the worst-case measurement (max Vin, 90°, hot restart) and compare each quantity with the limit that matches it:

LimitCompare withPass if
Product spec “max inrush”Measured peak, in the spec’s own time frame and exclusionsIpk ≤ limit, with margin (often 10 to 20 %)
FuseMeasured I²t of the whole eventI²t ≤ melting I²t × pulse factor (for example 22 % for 100,000 cycles)
Bridge rectifierFirst-pulse peak and I²tIpk ≤ IFSM (conservative) and I²t ≤ bridge I²t
NTCBulk capacitance and voltageWithin the max capacitance / energy rating
Relay / switchMeasured peak≤ inrush (make) rating
BreakerTotal inrush of all units on the circuitBelow the instantaneous trip level for the inrush duration (check the trip curve)
Time-current maskWhole measured waveformEvery point under the mask
NTC: Fuse: Life:
Fuse check using the measured I²t of the whole event. Fuse I²t values here are examples; use your fuse datasheet.
NTC: Input:
Checking a measurement against an example time-current mask: 100 A allowed up to 100 µs (filter spike), 35 A to 5 ms, 15 A to 100 ms, then 8 A.
If it fails: confirm the measurement first (probe range, zero, switch-on angle, source impedance). Then the usual fixes are a higher-resistance or higher-rated NTC, an active inrush limiter (relay or MOSFET with NTC/resistor bypass), less bulk capacitance, a time-lag fuse with higher I²t, or a bridge with a higher IFSM.

9. Step-by-Step Procedure and Report

  1. Estimate the worst-case peak with the calculator and choose the probe range and scale.
  2. Degauss and zero the current probe; clamp the line conductor. Line voltage on CH2 via a differential probe.
  3. Bandwidth limit OFF, DC coupling, sample mode, scale for about 5 div at the expected peak.
  4. Single shot, edge trigger (either slope) at ~10 % of the peak, 10 to 20 % pre-trigger, long record (≥ 0.5 s) at ≥ 1 MS/s.
  5. Cold start: bulk capacitor discharged, NTC at ambient. Switch on at 90° at max input voltage.
  6. Zoom and measure: X-cap spike, Ipk, time to peak, width, event duration, I²t, second events.
  7. Repeat at least 5 to 10 times; keep the maximum.
  8. Hot restart: run at full load until warm, off 1 to 2 s, on at 90°. Repeat and keep the maximum.
  9. Compare with every limit (spec, fuse, bridge, NTC, relay, breaker, mask) and record the margin.

Report template: input voltage and frequency, source type, switch-on angle, cold/hot, ambient, probe and range, Ipk (with exclusions), time to peak, width, duration, I²t, second-event peak, each limit and its margin, PASS/FAIL.

10. Common Mistakes and Fixes

MistakeResultFix
20 MHz limit or averaging onPeak reads lowBandwidth limit OFF, sample mode
Auto triggerEvent missed or overwrittenSingle shot
Random switch-on angle, one tryWorst case missedSwitch at 90° or repeat many times
Only cold startHot-restart peak missedTest a hot restart
Short capture windowSecond inrush (relay, PFC) missedCapture 0.5 to 1 s
Comparing peak with fuse ratingWrong conclusionCompare I²t with derated melting I²t
Including/excluding the X-cap spike inconsistentlyDisagreement with datasheetFollow the spec’s definition, report the spike separately
Probe range saturatedFlat-topped, low peakHigher current range
Weak source or isolation transformerInrush reads lowStiff source, or state the source impedance

11. Inrush Calculator: Estimate and Pass/Fail

Tab 1 estimates the inrush and suggests scope settings. Tab 2 checks your measured peak and I²t against the product spec, fuse, bridge rectifier and breaker.

Inrush Current Calculator: Estimate and Pass/Fail Check
Estimate the inrush before you measure, then check your measured values against each datasheet limit.

Related Guides

12. FAQ

How do you measure inrush current correctly?
Use a current probe (or shunt with a differential probe), DC coupling, bandwidth limit off, and single-shot trigger on the current at about 10 % of the expected peak with 10 to 20 % pre-trigger. Switch on at the peak of the line voltage at maximum input voltage, test both a cold start and a hot restart, and keep the highest result.
What time frame should I use to measure inrush current?
Use several views of one long capture: 10 to 50 µs/div for the EMI-filter spike, 0.5 to 2 ms/div for the main peak, 10 to 20 ms/div for the whole event and I²t, and 50 to 100 ms/div to catch second events such as relay bypass or PFC start-up.
Which inrush peak should I compare with the datasheet limit?
Normally the peak of the bulk-capacitor charging pulse. Read the datasheet footnotes: many specs exclude the very short EMI-filter capacitor charging spike, often described as lasting under a fraction of a millisecond. Report the spike separately.
How do I check if inrush will blow the fuse?
Compare the measured I²t of the whole inrush event with the fuse melting I²t multiplied by a pulse derating factor. A common fuse-maker guideline is about 38 % for 1,000 pulses, 29 % for 10,000 and 22 % for 100,000. Comparing the peak current with the fuse rating is not meaningful.
Is the bridge rectifier IFSM enough for my inrush?
IFSM is rated for an 8.3 ms or 10 ms half-sine pulse. Inrush pulses are usually shorter, so a peak below IFSM is a safe, conservative pass. For a peak above IFSM, compare the measured I²t with the bridge I²t rating.
Why is inrush higher on a hot restart?
An NTC thermistor’s resistance drops as it heats up. If the supply is switched off and on quickly after running, the hot NTC limits the current much less, so the peak can be several times the cold-start value.
Will several power supplies trip the breaker together?
Their inrush currents add when they are switched on at the same time. Compare the total with the breaker’s instantaneous trip level: 3 to 5 times In for type B, 5 to 10 for type C, 10 to 20 for type D, and check the trip curve for the inrush duration.
What sample rate do I need for inrush measurements?
At least 1 MS/s for the main capacitor-charging pulse, and 50 MS/s or more if you need to resolve the EMI-filter spike. Make sure the scope keeps that rate over the whole long capture by using deep memory.