LLC resonant converter design: half bridge with resonant capacitor, resonant inductor, transformer and synchronous rectifiers
Half-bridge LLC: the Cr, Lr and Lm tank gives zero-voltage switching across the load range.
Posted in

LLC Resonant Converter Calculator

LLC Resonant Converter Design Calculator

Half-bridge LLC with a center-tapped rectifier, with the tank derived from the spreadsheet method (λ from the maximum frequency, Q for no-load ZVS) or from Ln and a peak gain margin, then checked with first harmonic approximation (FHA). Enter your specs, then slide the bus voltage and load to watch the switching frequency, gain, ZVS, the resonant and magnetizing currents and the live circuit update.

1. Specifications
2. Transformer
3. Devices

Tank derivation (step by step)

Derived component values

Calculated from your specifications. These are exact values: choose real parts in the next section.

Turns ratio Np:Ns
Quality factor Q
Resonant capacitor Cr
Resonant inductor Lr
Magnetizing inductance Lm
Turns and flux
4. Actual components selected

Enter the real parts you will use, for example the nearest standard values. Leave 0 to keep the derived value. The gain curve, frequencies, currents, stresses and losses below are all calculated with these actual values.

Derived vs actual components
5. Operating point

    Live circuit

    Gain curve (FHA)

    Gain at this load (components used)Light load and full loadOperating pointRequired gain rangeDerived tank (dashed, shown when actual values differ)

    Operating point results (actual components)

    Switching frequency
    Required gain
    Resonant current
    Magnetizing current
    ZVS
    Output ripple

    Output capacitor, MOSFETs and rectifiers (with the actual components)

    Output capacitor
    MOSFETs Q1, Q2
    Output rectifiers

    Voltage and current of each device

    Power, losses and temperature

    Efficiency
    Pout ÷ Pin at this operating point.
    Input power
    Total loss
    MOSFET junction temp.
    MOSFET conductionMOSFET switchingCore, Lr and biasOutput rectifiersTransformer copperGate drive and Cout ESR

    Live waveforms

    FHA design with approximate time-domain waveforms. Real LLC gain differs from FHA, especially far below resonance and at light load, so confirm the design with simulation and measurement. Core loss and controller power are entered as an estimate. The half bridge runs from a high-voltage bus: build and test with proper safety precautions.