A Zeta converter produces a steady positive output voltage that can be above, equal to or below its input, and it delivers that output through an inductor, so the output current is smooth like a buck converter’s. That makes it a favourite for low-ripple step-up/step-down rails, LED drivers, battery chargers and point-of-load supplies that must run from a wide input range. It is sometimes called the “inverse SEPIC” because it swaps which side of the circuit has the continuous current. In this guide you will learn Zeta converter analysis and design step by step: how it works, the duty cycle and gain formula, how to size both inductors, the coupling capacitor and the input and output capacitors, high-side MOSFET and diode selection, power loss and efficiency, CCM and DCM, and stability. A complete worked example and a live calculator are included.
- The output is positive and can be above or below the input: Vout = Vin × D / (1 − D).
- It uses a high-side MOSFET, a diode, two inductors and a coupling capacitor C1.
- C1 charges to Vout, so it can be a low-voltage part.
- L2 makes the output current continuous (very low output ripple), but the input current is pulsed, like a buck.
- The switch and diode carry IL1 + IL2 and block Vin + Vout.
- When Q1 is off, the input is fully disconnected, which makes current limiting and short-circuit protection easy.
What Is a Zeta Converter?
A Zeta converter is a fourth-order, non-inverting buck-boost DC-DC converter. Its input side looks like an inverting buck-boost converter (a high-side switch with L1 to ground), and its output side looks like a buck converter (a diode and an output inductor L2). The coupling capacitor C1 links the two halves and flips the polarity back to positive.
It belongs to the same family as the SEPIC and the Ćuk converter. All three use two inductors and a coupling capacitor and share the same gain magnitude, D / (1 − D). The difference is where the smooth current is: the SEPIC has continuous input current, the Zeta has continuous output current, and the Ćuk has both but gives a negative output.
How a Zeta Converter Works
In steady state the coupling capacitor C1 holds a nearly constant voltage equal to Vout, with its positive side at node B. In DC terms, L1 and L2 are short circuits, so C1 is connected directly across the output. Each switching period has two states.
1. Switch ON (Q1 closed): energy flows from the input
Q1 connects node A to Vin. Two currents flow through Q1:
- Vin drives current down through L1 to ground, so IL1 ramps up, like the inverting buck-boost.
- Node B rises to Vin + Vout, so current flows from Vin through Q1, C1 and L2 into the load. L2 sees +Vin and IL2 ramps up, like a buck.
The diode is reverse biased because node B is far above ground. Q1 carries IL1 + IL2, and the input current is a series of pulses.
2. Switch OFF (Q1 open): the inductors freewheel
When Q1 opens, the input is completely disconnected. L1 keeps its current flowing by pulling it up from ground through the diode and C1, recharging C1. L2 keeps its current flowing into the load through the diode, exactly like a buck’s freewheeling diode. The diode carries IL1 + IL2, and both inductors see −Vout. Node A drops to −Vout.
Volt-second balance and the gain formula
Vin × D = Vout × (1 − D) → Vout = Vin × D / (1 − D) → D = Vout / (Vin + Vout)At D = 50% the output equals the input, below 50% it steps down and above 50% it steps up. Charge balance on C1 gives the current split:
IL2 × D = IL1 × (1 − D) → IL1 = Iin, IL2 = IoutZeta Converter Design Equations
Size L1, C1, the switch and the input capacitor at Vin(min), where the duty cycle and input current are highest. Size L2 and the output capacitor at Vin(max), where ripple is largest. Check voltage ratings at Vin(max).
| Parameter | Formula | Notes |
|---|---|---|
| Duty cycle | D = (Vout + Vf) / (Vin + Vout + Vf) | Vf = 0 for a synchronous design |
| Output voltage | Vout = Vin × D / (1 − D) | Positive, above or below Vin |
| L1 current | IL1 = Iin = Iout × (Vout + Vf) / Vin | Largest at Vin(min) |
| L2 current | IL2 = Iout | — |
| L1 | L1 = Vin(min) × D / (fsw × r × IL1) | Ripple ratio r = 0.2 to 0.4 |
| L2 | L2 = Vin(max) × D / (fsw × r × Iout) | Ripple largest at Vin(max) |
| Coupling capacitor voltage | VC1 = Vout | Rate for Vout plus margin |
| Coupling capacitance | C1 ≥ Iout × D / (fsw × ΔVC1) | ΔVC1 typically 2 to 5% of Vout |
| C1 ripple current | IC1(rms) = Iout × √(D / (1 − D)) | Can exceed Iout |
| Output capacitance | Cout ≥ ΔIL2 / (8 × fsw × ΔVout) | Same as a buck: output current is smooth |
| Output cap ESR | ESR ≤ ΔVout / ΔIL2 | Easy to meet with ceramics |
| Input capacitance | Cin ≥ Iout × D / (fsw × ΔVin) | Pulsed input current |
| Input ripple current | ICin(rms) = Iout × √(D / (1 − D)) | The hardest-working capacitor |
| Switch and diode voltage | V = Vin(max) + Vout + Vf | Add at least 30% margin |
| Switch and diode current | I = IL1 + IL2 = Iout / (1 − D) | Peak adds both ripples |
| CCM/DCM boundary | Iout(crit) = (1 − D) × (ΔIL1 + ΔIL2) / 2 | Below this, the diode current reaches zero |
| DCM duty cycle | D = √(2 × Le × fsw × Iout × Vout) / Vin | Le = L1 × L2 / (L1 + L2) |
Zeta Converter Design Example: 6–18 V to 9 V, 1 A
Let us design a low-ripple 9 V, 1 A (9 W) rail that runs from any input between 6 V and 18 V, for example a 2S to 4S lithium pack or a wide-range adapter input. The input crosses the output, and the 9 V rail feeds sensitive analog circuits, so smooth output current matters. The same values are loaded in the live calculator below.
| Specification | Value |
|---|---|
| Input voltage | 12 V nominal (6 V to 18 V) |
| Output voltage | 9 V |
| Output current | 1 A (9 W) |
| Switching frequency | 400 kHz |
| Ripple ratio | 30% for each inductor |
| Output ripple target | 20 mV peak-to-peak |
| Input ripple target | 100 mV peak-to-peak |
| C1 ripple target | 5% of Vout |
| Devices | High-side MOSFET Q1 (15 mΩ), Schottky diode (Vf 0.45 V) |
Step 1: Duty cycle
At Vin(min): D = (9 + 0.45) / (6 + 9 + 0.45) = 0.612, at Vin(max): D = 0.344At 12 V input the ideal duty cycle is 42.9%, or 44.2% with losses.
Step 2: Input-side inductor L1
IL1 = 1 × 9.45 / 6 = 1.58 A, L1 = 6 × 0.612 / (400 kHz × 0.3 × 1.58 A) = 19.4 µHRound up to 22 µH. The worst peak is 1.78 A, so choose a saturation current of at least 2.3 A.
Step 3: Output inductor L2
L2 = 18 × 0.344 / (400 kHz × 0.3 × 1 A) = 51.6 µHRound up to 56 µH with a saturation current of at least 1.5 A. As with the SEPIC and Ćuk, L1 and L2 can be wound on one core as a coupled inductor.
Step 4: Coupling capacitor C1
ΔVC1 = 5% × 9 V = 0.45 V, C1 ≥ 1 × 0.612 / (400 kHz × 0.45 V) = 3.4 µF, IC1(rms) = 1 × √(0.612 / 0.388) = 1.26 AUse 6.8 µF rated 16 V. C1 only sees Vout, which is the lowest voltage of the three coupled-capacitor converters, but it carries 1.26 A rms. Use X7R ceramics or a film capacitor.
Step 5: Output capacitor
ΔIL2 = 0.28 A, Cout ≥ 0.28 / (8 × 400 kHz × 20 mV) = 4.3 µF, ESR ≤ 20 mV / 0.28 A = 72 mΩUse 6.8 µF rated 16 V. The calculated ripple is about 11 mV at 12 V input. A SEPIC with the same output and ripple target would need about 76 µF, because its output current is pulsed.
Step 6: Input capacitor
Cin ≥ 1 × 0.612 / (400 kHz × 100 mV) = 15.3 µF, ICin(rms) = 1.26 AUse 33 µF rated 35 V with a ripple current rating above 1.3 A, placed right at Q1’s drain. This is where the Zeta pays for its quiet output: the input sees chopped current, just like a buck converter.
Step 7: MOSFET and diode
V = Vin(max) + Vout + Vf = 18 + 9 + 0.45 = 27.45 VWith 30% margin, use a 40 V MOSFET and a 40 V Schottky diode. Both carry IL1 + IL2, which peaks at about 2.9 A at 6 V input. Q1 is a high-side switch: use a P-channel MOSFET for simple low-voltage designs, or an N-channel MOSFET with a bootstrap or isolated gate driver for better efficiency.
Zeta Converter Loss and Efficiency Analysis
- Q1 conduction loss: IQ1(rms)² × Rds(on), with Q1 carrying IL1 + IL2.
- Q1 switching loss: ½ × (Vin + Vout + Vf) × t(edge) × fsw × (Ion + Ioff).
- Coss loss: ½ × Coss × (Vin + Vout)² × fsw.
- Gate drive loss: Qg × Vdrive × fsw, plus bootstrap or level-shift losses for the high-side driver.
- Diode loss: Vf × Iout.
- Inductor copper loss: IL1(rms)² × DCR1 + IL2(rms)² × DCR2, plus core loss.
- Capacitor ESR loss: mostly in C1 and Cin, which carry the pulsed currents.
For our example at 12 V input and 1 A, with 10 ns edges, 10 nC gate charge, 200 pF Coss, 5 V gate drive and 20 mΩ inductors:
| Loss source | Schottky diode (Vf 0.45 V) | Synchronous Q2 (15 mΩ) |
|---|---|---|
| Q1 conduction | 22 mW | 20 mW |
| Q1 switching + Coss | 172 mW | 165 mW |
| Gate drive | 20 mW | 40 mW |
| D1 forward drop / Q2 conduction | 450 mW | 27 mW |
| L1 + L2 DCR | 33 mW | 32 mW |
| Capacitor ESR | 8 mW | 8 mW |
| Total loss | 0.70 W | 0.29 W |
| Efficiency at 1 A | 92.7% | 96.9% |
With a Schottky diode, efficiency stays between about 92% and 93% across the whole 6 V to 18 V range. The diode loss is almost two-thirds of the total, because at a 9 V output its 0.45 V drop is a large fraction of the output. Core loss and the high-side driver’s own losses are not included, so expect real hardware to be one or two points lower.
Operating Modes: CCM and DCM
- Continuous Conduction Mode (CCM): the diode current IL1 + IL2 never reaches zero. Vout = Vin × D / (1 − D) holds and the equations above apply.
- Boundary Conduction Mode (BCM): the diode current just touches zero each cycle, at a load of (1 − D) × (ΔIL1 + ΔIL2) / 2, about 0.23 A in the example.
- Discontinuous Conduction Mode (DCM): below the boundary the diode turns off for part of each cycle. L1 and L2 then carry equal and opposite currents that circulate through C1, and the switch node rings around 0 V. The converter behaves like a buck-boost with Le = L1 × L2 / (L1 + L2).
- Forced PWM: a synchronous Zeta can let the rectifier current go negative instead, keeping the frequency fixed.
Drag the load slider in the calculator below to watch the circuit and inductor currents move from CCM into DCM.
Zeta Converter Control and Stability
Like the SEPIC and Ćuk, the Zeta is a fourth-order converter. Its L2–C1 resonance, about 1 / (2π√(56 µH × 6.8 µF)) ≈ 8 kHz in the example, and a right-half-plane zero limit the loop bandwidth. Most designs use current-mode control and keep the crossover at a few kilohertz, well below the resonance. A larger C1 lowers and damps the resonance, and an RC damping network across C1 can help further.
Zeta vs SEPIC vs Ćuk vs Four-Switch Buck-Boost
| Feature | Zeta | SEPIC | Ćuk | Four-switch buck-boost |
|---|---|---|---|---|
| Output polarity | Positive | Positive | Negative | Positive |
| Switch position | High-side | Low-side | Low-side | Two high-side, two low-side |
| Input current | Pulsed | Continuous | Continuous | Continuous in boost mode |
| Output current | Continuous | Pulsed | Continuous | Continuous in buck mode |
| Coupling cap voltage | Vout | Vin | Vin + |Vout| | None |
| Gate drive | High-side driver needed | Simple low-side | Simple low-side | Two high-side drivers |
| Output ripple | Low | High | Low | Low in buck mode |
| Typical efficiency | 88 to 94% | 88 to 94% | 88 to 95% | 95 to 98% |
| Best for | Quiet positive outputs, LED and battery charging | Simple, low-cost positive outputs | Quiet negative rails | High power, high efficiency |
If the input never crosses the output, a plain buck or boost converter is simpler, cheaper and more efficient.
Where Zeta Converters Are Used
- Low-ripple rails for analog, RF and sensor circuits from a wide-range input.
- LED drivers, where the smooth output current drives the LED string directly.
- Battery chargers that need a controlled, continuous charging current and input disconnect.
- Solar and PV systems, where the Zeta is often used as an MPPT stage feeding a battery or DC bus.
- Power factor correction and motor drives in some low-power designs.
PCB Layout Tips for Zeta Converters
- Keep the input hot loop tiny. Cin, Q1, C1 and the diode form the high di/dt loop. Place Cin right at Q1’s drain.
- Keep node A small. It swings from +Vin to −Vout every cycle.
- Route the high-side gate drive carefully. Keep the bootstrap capacitor and gate loop short.
- Place C1 between node A and the diode with short, wide traces, because it carries square-wave current.
- Take feedback from Cout, away from node A and the inductors.
Common Zeta Converter Design Mistakes
- Undersizing the input capacitor. It carries pulsed current like a buck’s input capacitor.
- Using an electrolytic capacitor for C1.
- Rating Q1 and the diode for Vin or Vout instead of Vin + Vout.
- Sizing Q1 and the diode for Iout instead of IL1 + IL2.
- Driving an N-channel high-side MOSFET without a proper bootstrap or isolated driver.
- Setting the loop crossover near the L2–C1 resonance.
Zeta Converter Design Checklist
- Define Vin range, Vout, Iout, ripple targets and fsw.
- Calculate D at Vin(min) and Vin(max).
- Size L1 at Vin(min) and L2 at Vin(max), or one coupled inductor. Rate for peak current.
- Size C1 for 2 to 5% ripple, rate it for Vout and its ripple current, and use ceramic or film.
- Size Cout for the small L2 ripple.
- Size Cin for pulsed input current and check its ripple current rating.
- Rate Q1 and the diode for Vin(max) + Vout + Vf and for IL1 + IL2.
- Choose a high-side drive method: P-channel, bootstrap or isolated driver.
- Estimate losses and efficiency across the input range.
- Keep the loop crossover well below the L2–C1 resonance and test across the full input range.
Try the Live Zeta Converter Design Calculator
Use the calculator below to design your own Zeta converter. Enter the input range, output voltage, load current, frequency and device parameters. It sizes both inductors, the coupling capacitor and the input and output capacitors, shows the voltage and current stress on every part, breaks down power loss and efficiency, estimates junction temperatures, detects the operating mode, and animates the live circuit and the switch node, L1 current, L2 current and output ripple waveforms.
Zeta Converter Design Calculator
Enter your specs. Every value, rating, loss and the live circuit and waveforms update as you type.
Live circuit
Operation mode: switching period
Component value selection
Voltage and current of each device
Power, losses and temperature
Live waveforms
Estimates for first-pass design. Core loss, diode reverse recovery, inductor coupling and layout parasitics are not modeled, so expect real efficiency a little lower. The output is positive. Q1 is a high-side switch, so it needs a P-channel MOSFET or a bootstrap or isolated gate driver. When Q1 is off, the input is fully disconnected from the output. Confirm with your controller datasheet.